Chaffer/Sieve Motor—Manual Adjust CAUTION:
 H75897-UN-09APR03
A - Cap Screws Shut OFF engine, set parking brake and remove key to help prevent accidental starting and personal injury.NOTE: Same manual adjust procedure can be used on the chaffer/sieve motor. Remove cap screws (A) to access motor.
IMPORTANT:  H74041-UN-05NOV02
A - Knob To prevent adjusting motor damage, do not use wrench on knob.NOTE: Once chaffer/sieve adjusting motor is repaired or replaced, adjusting motor will have to be recalibrated. (See Calibration Procedures section). Use knob (A) to adjust motor. Turn knob clockwise to close and counterclockwise to open chaffer/sieve.
| OUO6075,00009B4-19-20101206 |
|