Moisture Sensor Temperature Calibration H94478-UN-31MAR10
Diagnostic Icon  H94928-UN-11OCT10
A - Calibration Icon B - Calibrations Menu C - Enter/Accept Icon Touch or press confirm switch when diagnostic icon is highlighted.Touch or press confirm switch when calibration icon (A) is highlighted. Touch or press confirm switch when calibrations menu (B) is highlighted. Touch or press confirm switch when Moisture Sensor Temperature is highlighted. Touch or press confirm switch when enter/accept icon (C) is highlighted. NOTE:  H96030-UN-05OCT10
A - Plus (+) Icon B - Minus (-) Icon C - Sensor Temperature D - Offset E - Enter/Accept Icon Calibration must be done before harvesting begins and when moisture sensor is empty.Touch or press confirm switch when plus (+) icon (A) or minus (-) icon (B) is highlighted. NOTE: Sensor temperature must be set to the current ambient air temperature. Increase or decrease until desired sensor temperature (C) is shown. NOTE: Offset (D) automatically adjusts when ambient sensor temperature is set. Touch or press confirm switch when enter/accept icon (E) is highlighted to save sensor temperature. | OUO6075,0000746-19-20101005 |
|