NOTE:

H92727-UN-10SEP08
A - Nut
B - Valve Assembly
C - Cylinder
Water fire extinguisher is shipped uncharged. Prior to delivery
of machine the water fire extinguisher must be charged.When an antifreeze charge is used to freeze protect extinguisher,
a complete discharge and maintenance is required.
CAUTION: Before attempting to recharge ensure that extinguisher
is completely depressurized.
Discharge all remaining pressure and water (or antifreeze solution)
making sure that there is no remaining air pressure.
-
Loosen nut (A) and remove valve assembly (B) from cylinder (C).
-
IMPORTANT: Fire extinguisher must not be exposed to freezing
temperatures unless protected with antifreeze. See instructions decal
on extinguisher for further information.
NOTE: Corrosion inhibitor must be used, if water includes high
levels of chlorides (40 ppm).
Fill cylinder with 9.5 L (2.5 gal.) of clean water or antifreeze
solution.
NOTE: Fluid level will be approximately 15.2 cm (6 in.) below
the top of the cylinder.
-
CAUTION:

H92728-UN-08SEP08
A - Valve Assembly
B - Nut
C - Pressurizing Valve
Hand tighten nut to specification. Over tightening with wrench
will damage valve.
Install valve assembly (A) and tighten nut (B) to specification.
| Item | Measurement | Specification |
|
Nut | Torque | 11.3—11.9
N·m (100—105 lb-in) |
-
Remove cap from pressurizing valve (C).
-
NOTE: Set pressure regulator on air compressor to no more than
175 kPa (1.75 bar, 25 psi) higher than gauge operating pressure.
CAUTION: Never leave fire extinguisher connected to a regulator
of a high-pressure source for an extended period of time. Do not over
pressurize fire extinguisher. Fire extinguisher may rupture if over
pressurized.
Pressurize fire extinguisher to specification using air or nitrogen.
| Item | Measurement | Specification |
|
Fire Extinguisher | Pressure | 690 kPa 6.9 bar (100 psi) |
-
NOTE: Check nut, gauge, pressurizing valve, cylinder welds,
and valve orifice for leaks using leak detection fluid or a solution
of soapy water.
Install previously removed cap on pressurizing valve.
-

H92729-UN-08SEP08
A - Pin
B - Hose and Nozzle Assembly
C - Holder
Install pin (A) with ring facing towards front of extinguisher
and install tamper seal.
-
Install hose and nozzle assembly (B) in holder (C).
-
Install fire extinguisher on machine.