Batteries—Checking Specific Gravity
CAUTION: Batteries must be on a flat surface to accurately check
fluid levels. Battery fluid level should be visible at the top of
each fill port covering the plates in each cell. Battery
gas can explode. Keep sparks and flames away from batteries. Use a
flashlight to check battery electrolyte level.
Never check battery charge by placing a metal object across
the posts. Use a voltmeter or hydrometer.

TS182-UN-23AUG88
Check specific gravity of electrolyte in each cell with a
battery hydrometer to determine battery condition. Charge battery
if reading is below 1.225. Replace battery if difference between cells
is more than 0.050.
Always correct specific gravity reading for electrolyte temperature
variation. Add 0.004 for every 10°F above 80°F. (Add 0.007
for every 10°C above 27°C.) Subtract at same rate if electrolyte
temperature is below 80°F (27°C). Corrected specific gravity
of a fully charged battery is 1.265 — 1.280.
|
|
OUO6075,00007D9-19-20070319
|
|