Calibration Procedures - When to Calibrate
This list shows all possible calibrations. Depending on machine
options and header types, listing shown might not match calibration
menu shown on display.
NOTE: Error codes show on display if a problem exists during
a calibration procedure. Conditions causing error must be corrected
before continuing calibration.
-
Amber Flashers- Perform calibration
when control unit RC1, Amber Flasher bulbs, or associated components
are replaced/adjusted.
-
Corn Head Deck Plate Spacing Calibration
- Perform calibration when control unit LC1 or deck plate position
sensor or associated components are replaced/adjusted.
-
Feeder House Speed Calibration - Perform
calibration;
-
If control unit LC1 has been replaced.
-
First time each header is connected to combine.
-
If attachments of significant weight are added to or removed
from header.
-
Feeder House Tilt Calibration (If Equipped)
- Perform calibration;
-
If control unit LC1 has been replaced.
-
If lateral tilt sensor or associated components are replaced/adjusted.
-
Before connecting header to combine.
-
Feeder House Tilt Speed Calibration (If Equipped)
- Perform calibration;
-
If lateral tilt sensor or associated components are replaced/adjusted.
-
Before connecting header or first time header is connected to
combine.
-
Header Calibration - Perform calibration;
-
If control unit LC1 has been replaced.
-
If a header height control sensor or associated components are
replaced/adjusted.
-
First time each header is connected to combine.
-
NOTE: Mass Flow Vibration calibration must be performed when
changing headers and in every crop that is harvested.
Mass Flow Vibration Calibration (If Equipped)
- Perform calibration when control unit AYM or associated components
are replaced/adjusted.
-
Moisture Sensor Temperature (If Equipped)
- Perform calibration when control unit AYM or associated components
are replaced/adjusted.
-
NOTE: When prompted during self-leveling shoe calibration to
level chaffer/sieve, use switches on side of machine to level bays.
Self-Leveling Shoe Calibration (If Equipped)
- Perform calibration when control unit LC2 or chaffer/sieve
actuator has been replaced/adjusted or bays are not level.
-
Chaffer Opening Calibration - Perform
calibration when control unit LC2 or chaffer actuator has been replaced/adjusted
or louver openings are out of adjustment.
-
Sieve Opening Calibration - Perform
calibration when control unit LC2 or sieve actuator has been replaced/adjusted
or louver openings are out of adjustment.
-
IMPORTANT: Calibration should not be completed with round bar
concave covers installed. An incorrect zero position will result.
Threshing Clearance Calibration - Perform
calibration when control unit LC2, threshing clearance sensor, or
associated components are replace/adjusted.
-
Unloading Auger Engage Calibration - Perform calibration when control unit RC2, unloading auger belt
or associated components are replaced/adjusted.
-
NOTE: Yield calibration must be performed every year and in
every crop that is harvested to achieve accurate grain weight measurements.
Refer to Yield Calibration in CommandCenter Display Screens
section for more information.
Yield Calibration (If Equipped) - Perform
calibration when control unit AYM or associated components are replaced/adjusted.
-
Limited Accuracy - user calibration procedure has not been performed.
System defaults to a fixed internal calibration value which is not
adjustable.
-
Medium Accuracy - user has collected and selected one to three
loads. System uses these values to adjust the internal calibration
value.
-
Highest Accuracy - user has collected and selected a minimum
of four calibration loads. System uses these values to adjust the
internal calibration value.
NOTE: 13 load identification numbers can be saved before memory
is full and a load identification number must be deleted.
|
|