Preparing Machine for Storage
Swing out condenser and oil cooler and clean radiator with air,
water, or a vacuum cleaner.
Clean condenser and oil cooler after cleaning radiator. Clean
charge air cooler.
Every 60 to 90 days start engine and turn air conditioning ON.
Run engine at low idle for several minutes for compressor seal lubrication.
Outside temperature should be above 5 °C (40 °F) for proper
air conditioning operation.
Clean outside of engine with a safe solvent.
CAUTION: Do not use gasoline.
Clean inside of air cleaner and install new elements.
With engine warm, drain crankcase. Replace filter and fill with
correct oil. Add 0.66 L (22 oz.) of corrosion inhibitor to crankcase.
Run engine to circulate.
Drain, flush, and refill cooling system with 50/50 mixture of
antifreeze and water.
NOTE: Turn battery disconnect switch OFF if machine is stored
longer than 25 days. If storage period is longer than 90 days, remove
negative lead to batteries to minimize load to batteries.
Charge batteries completely. Specific gravity will equal 1.260
volts. Remove negative lead to batteries to minimize load to the batteries.
Drain water separator.
Clean machine inside and out. Leave elevator doors and drain
covers open.
Cycle concave up and down several times to prevent material
buildup in the concave area.
IMPORTANT: Directing pressurized water at electronic/electrical
components or connectors, bearings and hydraulic seals, fuel injection
pumps or other sensitive parts and components may cause product malfunctions.
Reduce pressure, and spray at a 45 to 90 degree angle.
Repaint areas where needed.
NOTE: It is not necessary to wax machine. However, if desired,
use a good clear wax that contains no abrasives. These type of waxes
usually do not contain cleaners.
Lubricate machine and grease adjusting bolt threads.
Perform all 400 hour (yearly) service.
Fill fuel tank to prevent condensation.
IMPORTANT: When fuel is stored in the machines fuel tank or
farms storage tank for extended periods, or if there is a slow turn
over of fuel, add a fuel conditioner to stabilize the fuel and prevent
water condensation. Contact your John Deere dealer for recommendations. For prolonged machine storage the best practice is to drain
bio-diesel and fill machine with regular petroleum diesel fuel. Otherwise
use bio-diesel stabilizer (anti-oxidant) additives or fully formulated
bio-diesel conditioners. Contact your John Deere dealer for recommendations.
If machine is to be stored for a long period of time remove
and clean batteries. Store them in a cool dry place and keep them
charged.
|
|
OUO6075,000111B-19-20120413
|
|