1534.01
|
Left-hand side header height sensor voltage is less than 0.50
V.
|
-
Adjust left-hand side height sensor minimum above 0.50 V with
linkage adjustment or rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
1534.00
|
Left-hand side header height sensor voltage is greater than
4.50 V.
|
-
Adjust left-hand side height sensor maximum below 4.50 V with
linkage adjustment or rotation of sensor.
-
Check for signal short to power.
|
|
1536.00
|
Center height sensor voltage is greater than 4.50 V.
|
-
Adjust sensor maximum below 4.50 V with linkage adjustment or
rotation of sensor.
-
Check for signal short to power.
|
|
1535.01
|
Right-hand side header height sensor voltage is less than 0.50
V.
|
-
Adjust sensor minimum above 0.50 V with linkage adjustment or
rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
1535.00
|
Right-hand side header height sensor voltage is greater than
4.50 V.
|
-
Adjust right-hand side height sensor maximum below 4.50 V with
linkage adjustment or rotation of sensor.
-
Check for signal short to power.
|
|
524278.01
|
Left-hand side header height sensor 2 voltage is less than 0.50
V.
|
-
Adjust left-hand side height sensor 2 minimum above 0.50 V with
linkage adjustment or rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
524278.00
|
Left-hand side header height sensor 2 voltage is greater than
4.50 V.
|
-
Adjust left-hand side height sensor 2 maximum below 4.50 V with
linkage adjustment or rotation of sensor.
-
Check for signal short to power.
|
|
524260.00
|
Center height sensor 2 voltage is greater than 4.50 V.
|
-
Adjust center height sensor 2 maximum below 4.50 V with linkage
adjustment or rotation of sensor.
-
Check for signal short to power.
|
|
524261.01
|
Right-hand side header height sensor 2 voltage is less than
0.50 V.
|
-
Adjust right-hand side height sensor 2 minimum above 0.50 V
with linkage adjustment or rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
524261.00
|
Right-hand side header height sensor voltage is greater than
4.50 V.
|
-
Adjust right-hand side height sensor maximum below 4.50 V with
linkage adjustment or rotation of sensor.
-
Check for signal short to power.
|
|
522779.11
|
Cutterbar pressure voltage is out of range. Calibration will
not proceed.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
1534.10
|
Left-hand side sensor raise voltage is less than lower voltage.
|
-
Incorrect sensor installed
-
Replace with correct sensor in parts catalog.
|
|
1536.10
|
Center height sensor raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
1535.10
|
Right-hand side sensor raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
524278.10
|
Left-hand side sensor 2 raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
524260.10
|
Center height sensor 2 raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
524261.10
|
Right-hand side sensor 2 raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
1534.07
|
Left-hand side height sensor voltage range is less than 1.20
V.
|
-
Check left-hand side height sensor linkage for structural failures,
failed springs or foreign objects preventing full travel of the linkage.
|
|
1536.07
|
Center height sensor voltage range is less than 1.20 V.
|
-
Check center sensor linkage for structural failures, failed
springs or foreign objects preventing full travel of the linkage.
|
|
1535.07
|
Right-hand side height sensor voltage range is less than 1.20
V.
|
-
Check right-hand side height sensor linkage for structural failures,
failed springs or foreign objects preventing full travel of the linkage.
|
|
524278.07
|
Left-hand side height sensor 2 voltage range is less than 1.20
V.
|
-
Check left-hand side height sensor 2 (Rigid Mode) linkage for
structural failures, failed springs or foreign objects preventing
full travel of the linkage.
|
|
524260.07
|
Center height sensor 2 voltage range is less than 1.20 V.
|
-
Check center sensor 2 (Rigid Mode) linkage for structural failures,
failed springs or foreign objects preventing full travel of the linkage.
|
|
524261.07
|
Right-hand side height 2 sensor voltage range is less than 1.20
V.
|
-
Check right-hand side height sensor 2 (Rigid Mode) linkage for
structural failures, failed springs or foreign objects preventing
full travel of the linkage.
|
|
Feeder House Range Cal First
|
Feeder house Range Calibration must be performed first.
|
-
Perform feeder house range calibration. Refer to combine operators
manual.
|
|
Feeder House Speed Cal First
|
Feeder house Speed Calibration must be performed first.
|
-
Perform feeder house speed calibration. Refer to combine operators
manual.
|
|
523271.00
|
Center height sensor 3 voltage is greater than 4.50 V.
|
-
Adjust center height sensor 3 maximum below 4.50 V with linkage
adjustment or rotation of sensor.
-
Check for signal short to power.
|
|
523271.10
|
Center height sensor 3 raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
523271.07
|
Center height sensor 3 voltage range is less than 1.20 V.
|
-
Check center height sensor 3 linkage for structural failures,
failed springs or foreign objects preventing full travel of the linkage.
|
|
1517.01
|
Lift cylinder pressure range is less than 690 kPa (100 psi)
(6.9 bar).
|
-
Check sensor plug in signal wire for shorts to ground or power.
-
Replace sensor.
|
|
523271.01
|
Center height sensor 3 is out of range - less than 0.50 VDC.
|
-
Adjust center height sensor 3 minimum above 0.50 V with linkage
adjustment or rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
1536.01
|
Center height sensor is out of range - less than 0.50 VDC.
|
-
Adjust center height sensor minimum above 0.50 V with linkage
adjustment or rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
3333.07
|
Feeder house raise/lower system has a valve fault.
|
-
Contact your local John Deere dealer.
|
|
524260.01
|
Center height sensor 2 is out of range - less than 0.50 VDC.
|
-
Adjust center height sensor 2 minimum above 0.50 V with linkage
adjustment or rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
523586.01
|
Reel height position sensor is out of range - less than 0.50
VDC.
|
-
Adjust sensor minimum above 0.50 V with linkage adjustment or
rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
523555.01
|
Reel extend/retract position sensor is out of range - less than
0.50 VDC.
|
-
Adjust sensor minimum above 0.50 V with linkage adjustment or
rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|