524261.01
|
Right-hand side header height sensor 2 voltage is less than
0.50 V
|
-
Adjust right-hand side height sensor minimum above 0.50 V with
linkage adjustment or rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
524261.00
|
Right-hand side header height sensor voltage is greater than
4.50 V
|
-
Adjust right-hand side height sensor maximum below 4.50 V with
linkage adjustment or rotation of sensor.
-
Check for signal short to power.
|
|
522779.11
|
Cutterbar pressure voltage is out of range. Calibration will
not proceed.
|
-
Verify that the sensor is plugged into the header harness.
-
Check sensor power and signal for shorts and shorts to ground.
|
|
1534.10
|
Left-hand side header height sensor raise voltage is less than
lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
1536.10
|
Center height sensor raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
1535.10
|
Right-hand side sensor raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
524278.10
|
Left-hand side sensor 2 raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
524260.10
|
Center height sensor 2 raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
524261.10
|
Right-hand side sensor 2 raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
1534.07
|
Left-hand side height sensor voltage range is less than 1.20
V.
|
-
Check left-hand side sensor linkage for structural failures,
failed springs or foreign objects preventing full travel of the linkage.
|
|
1536.07
|
Center height sensor voltage range is less than 1.20 V.
|
-
Check center sensor linkage for structural failures, failed
springs or foreign objects preventing full travel of the linkage.
|
|
1535.07
|
Right-hand side height sensor voltage range is less than 1.20
V.
|
-
Check right-hand side sensor linkage for structural failures,
failed springs or foreign objects preventing full travel of the linkage.
|
|
524278.07
|
Left-hand side height sensor 2 voltage range is less than 1.20
V.
|
-
Check left-hand side height sensor 2 linkage for structural
failures, failed springs or foreign objects preventing full travel
of the linkage.
|
|
524260.07
|
Center height sensor 2 voltage range is less than 1.20 V.
|
-
Check center height sensor 2 linkage for structural failures,
failed springs or foreign objects preventing full travel of the linkage.
|
|
524261.07
|
Right-hand side height sensor 2 voltage range is less than
1.20 V.
|
-
Check right-hand side height sensor 2 linkage for structural
failures, failed springs or foreign objects preventing full travel
of the linkage.
|
|
523271.00
|
Center height sensor 3 voltage is greater than 4.50 V.
|
-
Adjust center height sensor 3 maximum below 4.50 V with linkage
adjustment or rotation of sensor.
-
Check for signal short to power.
|
|
523271.10
|
Center height sensor 3 raise voltage is less than lower voltage.
|
-
Incorrect sensor installed.
-
Replace with correct sensor in parts catalog.
|
|
523271.07
|
Center height sensor 3 voltage range is less than 1.20 V.
|
-
Check center height sensor 3 linkage for structural failures,
failed springs or foreign objects preventing full travel of the linkage.
|
|
1517.01
|
Lift cylinder pressure range is less than 100 psi (6.9 bar).
|
-
Check sensor plug in signal wire for shorts to ground or power.
-
Replace sensor.
|
|
523271.01
|
Center height sensor 3 is out of range - less than 0.50 VDC.
|
-
Adjust center height sensor 3 minimum above 0.50 V with linkage
adjustment or rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
1536.01
|
Center height sensor is out of range - less than 0.50 VDC.
|
-
Adjust center height sensor minimum above 0.50 V with linkage
adjustment or rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
3333.07
|
Feeder house raise/lower system has a valve fault.
|
-
Contact your local John Deere dealer.
|
|
524260.01
|
Center height sensor 2 is out of range - less than 0.50 VDC.
|
-
Adjust center height sensor 2 minimum above 0.50 V with linkage
adjustment or rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
523586.01
|
Reel height position sensor is out of range - less than 0.50
VDC.
|
-
Adjust sensor minimum above 0.50 V with linkage adjustment or
rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
523555.01
|
Reel extend/retract position sensor is out of range - less than
0.50 VDC.
|
-
Adjust sensor minimum above 0.50 V with linkage adjustment or
rotation of sensor.
-
Verify that sensor is plugged into harness.
-
Check for signal short to ground or power short to ground.
|
|
1519.13
|
Feeder house speed calibration must be performed first.
|
Refer to combine operators manual/technical manual for troubleshooting.
|
|
3333.13
|
Feeder house range calibration must be performed first.
|
Refer to combine operators manual/technical manual for troubleshooting.
|