Leveling Platform to Ground
If combine is not equipped with lateral tilt feeder house it
is essential to level platform when cutting on the ground.
NOTE: Before performing leveling procedures, park machine on
a flat, level surface.
Side-to-Side Leveling
-
Lower platform until cutterbar is approximately 457 mm (18 in.)
off the ground.
-
Measure distance from extreme right knife guard to the ground.
Repeat measurement on extreme left-hand guard. If these two dimensions
are significantly different, it is necessary to reset cutterbar level.
This adjustment is typically accomplished through adjustments
at the feeder house. Refer to combine Operator's Manual for procedure.
Front-to-Back (Fore/Aft) Leveling with Manual
Fore/Aft Feeder House
The HydraFlex draper front to back engagement angle is designed for optimum performance
on your combine. It is recommended that the factory feeder house fore/aft
tilt frame setting be used. If adjustments are desired or if ground
following performance is questionable, refer to your combine Operator's
Manual for instruction.
Tilting the feeder house forward from this position is not recommended.
Excessive forward tip can cause material to push ahead of the guards
ultimately leading to lost uncut crop.
Tilting the feeder house rearward from this position is not
recommended. Excessive rearward tilt may result in the frame assembly
to be inadvertently pushed into the ground. This causes debris and
soil to collect on or in the draper belts and float system. This adjustment
also adversely affects performance and causes side draper belts to
stall.
Front-to-Back (Fore/Aft) Leveling with Hydraulic
Fore/Aft Feeder House
If HydraFlex™ draper is used with a combine that has hydraulic
fore/aft tilt feeder house, run tilt angle at a 0 degree tilt for
best results in most field conditions. If ground performance is questionable,
draper can be tilted forward or rearward as needed .
|