IMPORTANT: Do not add chemical to solution tank until just before
field use. Follow the chemical manufacturer's instructions for mixing
the spray solution to obtain the desired application rate and effect.
-
NOTE: Solution tank is full and engine is running.
Eductor performance may be diminished somewhat with a full tank.

N63883-UN-10SEP03

N63882-UN-11NOV03

N63884-UN-10SEP03
A - Eductor
B - Eductor Switch
C - Eductor Hopper Valve
D - Eductor Rinse Valve
E - Rinse Nozzle
Lower eductor (A) and raise lid.
-
Move eductor switch (B) to “ON” position.
NOTE: Engine speed will automatically increase to 1800 rpm.
-
Open eductor hopper valve (C) (handle parallel with solution
hose) to allow chemicals to be drawn from eductor hopper.
-
Pour chemicals into eductor.
-
Open eductor rinse valve (D) (turn clockwise) to rinse eductor
hopper.
-
Place chemical container over rinse nozzle (E) in hopper and
push down on container to rinse.
-
After rinsing chemical containers, close eductor rinse valve.
-
Turn eductor switch to “OFF” position.
-
Close eductor hopper valve.
-
Place lid back on hopper and return eductor back to its original
position.