Using Eductor To Load Chemicals with Full Solution Tank

CAUTION: Read carefully the directions printed on the chemical manufacturer's labels before handling chemicals or you may be exposed to hazardous materials which could poison and injure you.

IMPORTANT: Do not add chemical to solution tank until just before field use. Follow the chemical manufacturer's instructions for mixing the spray solution to obtain the desired application rate and effect.

  1. NOTE: Solution tank is full and engine is running.

    Eductor performance may be diminished somewhat with a full tank.

    N63883
    N63883-UN-10SEP03

    N63882
    N63882-UN-11NOV03

    N63884
    N63884-UN-10SEP03

    A - Eductor

    B - Eductor Switch

    C - Eductor Hopper Valve

    D - Eductor Rinse Valve

    E - Rinse Nozzle

    Lower eductor (A) and raise lid.



  2. Move eductor switch (B) to “ON” position.

    NOTE: Engine speed will automatically increase to 1800 rpm.

  3. Open eductor hopper valve (C) (handle parallel with solution hose) to allow chemicals to be drawn from eductor hopper.

  4. Pour chemicals into eductor.

  5. Open eductor rinse valve (D) (turn clockwise) to rinse eductor hopper.

  6. Place chemical container over rinse nozzle (E) in hopper and push down on container to rinse.

  7. After rinsing chemical containers, close eductor rinse valve.

  8. Turn eductor switch to “OFF” position.

  9. Close eductor hopper valve.

  10. Place lid back on hopper and return eductor back to its original position.

OUO6092,0000459-19-20040823