Before Field Operation
NOTE: Verify machine is properly prepared for field operation.
Check the following items before operating:
CAUTION: Do not turn on the machine until you are sure nobody
is in the danger zone.
-
All maintenance has been performed.
-
Correct nozzle tips are installed and set for desired spray
pattern and row spacing. (See Wet System section for proper nozzle
tip and row spacing selection.)
-
Wheel tread width is adjusted for row spacing. See Use Tread
Adjust in Chassis section of this manual.
-
SprayStar display has been correctly programmed with the following:
(See SprayStar System section to program information properly.)
-
Application Rates
-
Tank Volume
-
Minimum Spray Pressure
-
Spray Off Pressure
-
Number of Boom Sections
-
Nozzle Spacing
-
Spray Width
-
Check Flowmeter Calibration Number
-
Calibrate Pressure Sensor
-
Calibrate Wheel Speed Sensor
-
Calibrate Radar Sensor (if equipped)
-
Perform the Boom Air Bleed Process in Recommendations For Eliminating
Air from Solution System in the Wet system section.
-
Solution tank is filled, solution valves are correctly positioned
and agitation valve (if necessary) is open. (See Wet System section.)
-
Operator is familiar with all machine controls, their functions,
and safe operations. (See Chassis and Safety sections.)
-
Clean water tank is filled with clean water. (See Clean Water
Tank in the Wet System section.)
|
|
CS12167,000017F-19-20130501
|
|