Calibrate Nozzles


Frequency of Calibration

Even though a sprayer's operation can be theoretically determined using mathematical formulas, there are still many reasons to verify that the output is what it should be. For example,

  • wear (especially on nozzles)
  • damaged or malfunctioning parts (such as pressure gauges)
  • plugged or restricted passages (such as strainers and hoses)

Obviously, pre-season visual checks are not adequate for accurate application, nor is the fact that equipment and nozzle tips are new. Also, manufacturer's catalogs are only guidelines; fine-tuning a sprayer is the operator's responsibility.

A sprayer's output should be checked:

  • after any adjustments
  • when switching to a new chemical or application rate
  • after a week of continuous use under the same circumstances

Verifying the results of an adjustment is standard procedure for all John Deere products. Never make adjustments to a sprayer without then verifying the output from the nozzles.

Cost

Resulting In:

Wasted Resources

Over-or-under-application of expensive chemicals

Reduced Yield/Quality

Chemical stress, pest pressure remaining

Effect on Future Crops

Chemical carryover

CS12167,00002D3-19-20130104