Drain Solution Tank—EU Machines Only
CAUTION:

N105941-UN-16SEP13
A - Drain Valve
B - Cap
Spray system can contain hazardous material which can cause
serious injury or death to you or others. Wear protective clothing,
eyewear, and gloves. Drain solution tank in an area where people,
animals, vegetation and water supply etc., cannot be contaminated.
-
CAUTION: Drain valve can contain hazardous materials which can
poison causing serious injury or death to you or others. Before removing
cap (B), make sure drain valve is turned off. Do not
drain solution onto the ground. Drain into a suitable container.
Verify drain valve (A) is closed.
-
Open lock levers and remove cap (B).
-
Connect nurse tank hose to drain valve or place suitable container
under drain valve to catch solution.
-
Open drain valve.
-
After solution has drained close drain valve and remove nurse
tank hose (if used).
-
Install drain valve cap.
|
|
CS12167,0000561-19-20140203
|
|