BoomTrac Pro Setup Page

N104107-UN-04JUN13
Select the Setup softkey or press BoomTrac Pro button on Sprayer
Main Page to access page.
On BoomTrac Pro Page the following are displayed and can be
changed:
Sensor Target Mode (A)— This
section allows the user to select between “Canopy” and
“Ground” modes of operation.
“Canopy” mode causes a boom height sensor to react
to the first thing it sees looking vertically to the ground. This
mode can be used to maintain a boom height relative to the top of
the crop canopy or to the ground if no crop exists.
“Ground” mode causes a boom height sensor to look
past the first obstacle it sees looking vertically to the ground.
This mode can be used to maintain the boom height relative to the
ground when there is crop present in the field. It is important to
note that in dense crop conditions, the boom height sensors may not
be able to see the ground. In this case, it is better to run in canopy
mode and maintain some distance between the booms and the top of the
crop canopy.
Raise Response (B)— Allows operator
to adjust the response sensitivity of the boom raise function. Operator
can choose from settings 1-5, with 5 being the most sensitive (if
performance is unstable, try a lower setting to improve).
Lower Response (C)— Allows operator
to adjust the response sensitivity of the boom lower function. Operator
can choose from settings 1-5, with 5 being the most sensitive (if
performance is unstable, try a lower setting to improve).
Target Height Input Mode (D)— This section allows the user to select between “Match Center
Frame” and “Individual” modes of operation.
-
Match Center Frame mode—matchs the left and right target
heights to the center frame target height (E). In this mode, the center
frame height (40) is highlighted. This is the only height the user
can modify when operating in this mode.
-
Individual mode—allows the user to individually change
the target height of each boom section (i.e. left boom, right boom,
and center frame).
NOTE: The target heights here are the distance from the bottom
of the nozzle tips to the target (ex. crop canopy, ground).
BoomTrac Enabled (F)— When checked
this allows the system to be activated using the resume button on
the multifunction control handle. Unchecking the box keeps the system
from turning on using the multifunction control handle resume button.
Center Frame Control (G)— When
checked it allows the center frame to actively control up and down
through the field based on the center frame sensor. In some conditions
it may be beneficial to uncheck this box to keep the center frame
from over-controlling. When unchecked the center frame will control
once to target height and stop.
Roll Sensor Reading (H)— on
the center frame. The value should be "0" when booms are unfolded
and level. The value should be positive when the center frame rolls
clockwise and negative when rolled counterclockwise.
Boom Section Softkey (I)— allows
operator to access sensor setup page.
Operator can set the serial numbers for the sensors, enable\disable
sensors and view sensor information.
BoomTrac Status (J)— allows
operator to access status page.
Select Enter button (K) to return to Sprayer Main Page.
|
|
CS12167,0000765-19-20150330
|
|