Perform System Pressurization Check

CAUTION: Read carefully the directions printed on the chemical manufacturer's labels before handling chemicals or you may be exposed to hazardous materials which could poison and injure you.

IMPORTANT: Do not add chemical to solution tank until just before field use. Follow the chemical manufacturer's instructions for mixing the spray solution to obtain the desired application rate and effect.

Perform system pressurization check if solution system has been repaired or serviced to ensure that no leaks are present. System pressurization check can also be used to verify that solution pump is capable of creating desired pressure.

  1. N94528
    N94528-UN-21SEP11

    A - Pump Button

    B - Pump Speed Increase Button

    C - Pump Speed Decrease Button

    Press pump button (A).



  2. Adjust pump speed if desired using buttons (B) and (C).

  3. Press pump button to stop check.

KB78086,0000B4C-19-20130618