Drain Moisture From Load Command Pump Oil—250 Hours
NOTE: Presence of moisture or milky oil can be identified as
normal. Drain moisture and fill to proper oil level every 250 hours.
-

N86784-UN-05NOV09
A - Plug
B - Plug
C - Plug
Remove plug (A) and drain moisture collected in tube. Replace
plug.
-
Remove plugs (B and C).
-
Refill pump through plug (C) to fill level (B) using GL5 80W-90
gear lube. Replace plugs.
|
|
OUO6092,00002A6-19-20091105
|
|