CAUTION: Read carefully the directions printed on the chemical
manufacturer's labels before handling chemicals, exposure to hazardous
materials could cause injury or death.
IMPORTANT: Do not add chemical to solution tank until just before
field use. Follow the chemical manufacturer's instructions for mixing
the spray solution to obtain the desired application rate and effect.
CAUTION: Quik-Fill valve (A) can contain hazardous materials
which can poison causing serious injury or death to you or others.
Before removing Quik-Fill cap (B), verify Quik-Fill valve is closed.

N98785-UN-12JUL13
Side Quik-Fill

N106681-UN-24SEP13
A - Quik-Fill Valve
B - Cap
C - Solution Tank Sump Valve
Verify Quik-Fill valve (A) is closed.
-
Open lock levers and remove cap (B).
-
Connect nurse tank fill hose to Quik-Fill adapter and close
lock levers.
-
Open solution tank sump valve (C).
-
Open Quik-Fill valve and nurse tank valve.
-
NOTE: Operator must monitor solution tank content volume to
prevent overfilling solution tank. When using an external pump
source, the sight gauge may give erratic volume readings. Therefore,
a flowmeter is recommended to accurately monitor tank fill.
Fill using nurse pump.
-
After solution tank has filled, shut down nurse tank pump and
close nurse tank valve.
-
Close Quik-Fill valve and solution tank sump valve.
-
Remove fill hose from Quik-Fill adapter and replace cap.