Park machine and shut off the engine.
-
Remove the ignition key from the key switch.
-
Access the engine compartment. (See Access to Engine Compartment
in Access to Service Points section.)
-
Open the bleed screw (A).

CQ289225-UN-16DEC10
A - Bleed Screw
-
Turn the ignition key to the run position.
-
Wait 40 s.
-
Turn the ignition key to the off position.
-
Close the bleed screw (A).
-
Start up the engine and let it run for a few minutes.
IMPORTANT: Do not engage the starter motor for more than 30
s. If the engine does not start, wait 2 min then repeat the operation.
-
If the engine does not start, repeat the procedure.