Adjusting Feed Auger Springs
Tighten or loosen the adjusting nuts (B) to obtain spring length (A; between hooks) of 240 mm (9.5 in.).
Tighten the lock nut to keep this adjustment.
Repeat procedure on the opposite side.
NOTE:
The feed auger spring adjustment described above is a basic adjustment. Readjust according to field conditions (reduce spring tension for high yield).
|