Adjusting Feed Auger Springs

Tighten or loosen the adjusting nuts (B) to obtain spring length (A; between hooks) of 240 mm (9.5 in.).

Tighten the lock nut to keep this adjustment.

Repeat procedure on the opposite side.

NOTE: The feed auger spring adjustment described above is a basic adjustment. Readjust according to field conditions (reduce spring tension for high yield).

CC1022186


A-Spring length
B-Adjusting nut

CC03745,000050B -19-12AUG03-1/1