Accessing Addresses and Diagnostic Trouble Codes
Procedure for dealing with diagnostic trouble codes
Every control unit monitors certain electrical circuits within
the network of circuits for which it is responsible. The unit then
stores the relevant diagnostic trouble code if there is a malfunction
(error) or if the operator makes a mistake. However, not all of the
diagnostic trouble codes indicate a current problem, since most of
the circuits are monitored only at the actual moment of activation
or when they are actually activated (switched on). To make sure that
the diagnostic trouble code you are troubleshooting is "active", you
should proceed as follows:
-
Accessing diagnostic trouble codes
-
Note and clear the diagnostic trouble code(s)
-
Activate the circuit affected (functional check).
-
Access the diagnostic trouble codes again and process them
If it is not possible to (re-)produce a relevant diagnostic
code by means of a functional check and the problem is still present
in the circuit, deal with the codes you noted earlier.
Accessing
the diagnostic codes of all control units (ALL mode)
1 Accessing the ALL
mode
Before entering program mode, see "General Operating Instructions
and Entering Program Mode".
Digital display:
Move the turn signal lever up or down (to positions for left
or right turn signals).
Performance monitor:
Press "2" key or "0" key.
Display:
- - - : ALL
Enter the ALL mode. GO TO: 2.
Contact dealer.
2 Entering the ALL mode
Digital display:
Turn the hazard flasher switch on/off.
Performance monitor:
Press the "Set/Save" key.
Display:
000 : ALL
Check the individual control units. GO TO: 3.
Leave the ALL mode. GO TO: 7.
GO TO: Canceling or completing the program mode.
3 Checking the individual
control units
Digital display:
Move the turn signal lever up or down (to positions for left
or right turn signals).
Performance monitor:
Press "2" key or "0" key.
Display:
The first control unit appears on the display
e.g.: BCU : nonE
or
e.g.: BCU : CodE
If display shows: nonE, GO TO: 4.
If display shows: CodE, GO TO: 5.
4 No diagnostic trouble
codes are stored (nonE)
Digital display:
Move the turn signal lever up or down (to positions for left
or right turn signals).
The next control unit appears on the display.
Performance monitor:
Press "2" key or "0" key.
The next control unit appears on the display.
Check the next control unit, GO TO: 3.
Leave the ALL mode. GO TO: 7.
GO TO: Accessing and confirming a control unit.
GO TO: Canceling or completing the program mode.
5 Diagnostic trouble
codes are stored (CodE)
Digital display:
Turn the hazard flasher switch on/off.
Performance monitor:
Press the "Set/Save" key.
Display:
The first diagnostic trouble code appears on the display. For
an explanation of the diagnostic trouble codes, see "Diagnostic Trouble
Codes on Basic Control Unit / Hitch Control Unit (BCU)" and the text
thereafter.
Digital display:
Move the turn signal lever up.
Performance monitor:
Press "2" key.
Display:
The next diagnostic code appears on the display.
Repeat this procedure until the display reads: CLr?
Clear the diagnostic trouble codes. GO TO: 6.
GO TO: Canceling or completing the program mode.
6 Clearing diagnostic
trouble codes
Digital display:
When CLr? appears on the display, switch the hazard flasher
switch on/off.
Performance monitor:
When "CLr?" appears on the display, press the "Set/Save" button.
Display:
donE
Check the next control unit, GO TO: 3.
Leave the ALL mode. GO TO: 7.
GO TO: Accessing and confirming a control unit.
GO TO: Canceling or completing the program mode.
7 Leave the ALL mode
Digital display:
Pull the turn signal lever (flash-to-pass) towards the steering
wheel for at least 2 seconds.
Performance monitor:
Press "Clear" key.
Display:
- - - : ALL
GO TO: Accessing and confirming a control unit.
GO TO: Canceling or completing the program mode.
Accessing
and confirming a control unit
1 Accessing a control
unit
Before entering program mode, see "General Operating Instructions
and Entering Program Mode".
Digital display:
Repeatedly move the turn signal lever upward (right turn signal
position) until the desired control unit is displayed.
Performance monitor:
Keep pressing the "2" key until the desired control unit appears
on the display.
Display:
The control units appear on the display.
e.g.: - - - : BCU
The "01" after the dot that appears in the performance
monitor's display indicates how many times the control unit is located
on the BUS lines.
Abbreviations Used in Display
|
Display
|
Meaning
|
|
|
BCU
|
(Basic Control Unit / Hitch Control Unit)
|
Basic control and rockshaft control unit
|
|
BIF
|
(Basic Informator)
|
Basic informator
|
|
EPC
|
(Electronic PowrQuad Controller)
|
Electronic control unit for PowrQuad Plus and transmission
|
|
PrF
|
(Performance Monitor)
|
Performance monitor
|
| |
|
|
|
DIA
|
(Diagnosis)
|
Diagnostics
|
|
NONE
|
(None)
|
No diagnostic trouble code stored
|
|
CODE
|
(Code)
|
Diagnostic trouble code stored
|
|
InP
|
(Input)
|
Key in
|
|
CAL
|
(Calibration)
|
Calibration
|
|
EOC
|
(End of Calibration)
|
End of calibration
|
|
End
|
(End)
|
End of a sequence of numbers
|
|
Err
|
(Error)
|
Fault
|
Confirm the control unit. GO TO: 2.
Contact dealer.
2 Confirming the control
unit
Digital display:
Turn the hazard flasher switch on/off.
Performance monitor:
Press the "Set/Save" key.
Display:
e.g.: 000 : BCU.01
Change the control unit. GO TO: 3.
GO TO: Accessing diagnostic trouble codes of the individual
control units.
GO TO: Accessing addresses.
GO TO: Canceling or completing the program mode.
3 Changing the control
unit
Digital display:
Pull the turn signal lever (flash-to-pass) towards the steering
wheel for at least 2 seconds.
Performance monitor:
Press "Clear" key.
Display:
e.g.: - - - : BCU
Access diagnostic trouble codes. GO TO: 1.
Accessing
diagnostic trouble codes of the individual control units
1 Accessing diagnostic
trouble codes
Before entering program mode, see "General Operating Instructions
and Entering Program Mode".
Digital display:
Move the turn signal lever up (right turn signal position).
Performance monitor:
Press "2" key.
Display:
The display indicates whether diagnostic trouble codes have
been saved in the selected control unit.
e.g.: BCU : nonE or
e.g.: BCU : CodE
If display shows: nonE, GO TO: 2.
If display shows: CodE, GO TO: 3.
2 No diagnostic trouble
codes are stored (nonE)
Digital display:
Move the turn signal lever up (right turn signal position).
Performance monitor:
Press "2" key.
GO TO: Accessing addresses.
GO TO: Canceling or completing the program mode.
3 Diagnostic trouble
codes are stored (CodE)
Digital display:
Turn the hazard flasher switch on/off.
Performance monitor:
Press the "Set/Save" key.
Display:
The first diagnostic trouble code appears on the display. For
an explanation of the diagnostic trouble codes, see "Diagnostic Trouble
Codes on Basic Control Unit / Hitch Control Unit (BCU)" and the text
thereafter.
Digital display:
Move the turn signal lever up.
Performance monitor:
Press "2" key.
Display:
The next diagnostic code appears on the display.
Repeat this procedure until the display reads: CLr?
Clear the diagnostic trouble codes. GO TO: 4.
GO TO: Canceling or completing the program mode.
4 Clearing diagnostic
trouble codes
Digital display:
When CLr? appears on the display, switch the hazard flasher
switch on/off.
Performance monitor:
When "CLr?" appears on the display, press the "Set/Save" button.
Display:
donE
GO TO: Accessing addresses.
GO TO: Canceling or completing the program mode.
Accessing
addresses
1 Selecting the desired
address
Select the desired address.
There are different types of addresses.
-
Display addresses: They only show information.
-
Input addresses: These are used to configure the control unit
for the appropriate tractor model and installed accessories. If the
address is an input address, "InP" appears in the display.
If it is a display address, GO TO: 2.
If it is an input address (InP), GO TO: 3.
2 Accessing display addresses
Before entering program mode, see "General Operating Instructions
and Entering Program Mode".
Digital display:
Move the turn signal lever up or down (to positions for left
or right turn signals) until the desired address appears.
Performance monitor:
Press "2" key or "0" key until the desired address is displayed.
Display:
The address appears in the display.
GO TO: Canceling or completing the program mode.
GO TO: Accessing addresses.
3 Accessing input addresses
(InP)
Before entering program mode, see "General Operating Instructions
and Entering Program Mode".
Digital display:
Move the turn signal lever up or down (to positions for left
or right turn signals) until the desired input address appears.
Performance monitor:
Press "2" key or "0" key until the desired input address is
displayed.
Display:
The input address appears in the display. InP also appears.
Changing an input address (InP), GO TO: 4.
4 Changing an input address
(INP)
Digital display:
Turn the hazard flasher switch on/off.
Performance monitor:
Press the "Set/Save" key.
Display:
All the display positions in the input address start to flash.
Select information (data in figures). GO TO: 5.
5 Selecting information
(numerical value)
Digital display:
Move the turn signal lever up or down (to positions for left
or right turn signals) until the desired numerical data appears.
Pull the turn signal lever (flash-to-pass) briefly towards the
steering wheel.
The next display position starts to flash.
Keep repeating this procedure until all the display positions
are showing the correct figures.
To save this information, turn the hazard flasher switch on/off.
Performance monitor:
Key in the numerical data directly at the numbered keys.
After every input, the display automatically jumps to the next
display position. All the display positions in the input address flash
during input.
To save this information, press the "set/save" key.
Display:
The display positions on the display stop flashing.
GO TO: Canceling or completing the program mode.
GO TO: Accessing addresses.
Canceling
or completing the program mode
1 Canceling the program
mode
Diagnostics or input can be canceled at any time. However,
if any data have been changed but not stored prior to ending input,
these changes are lost.
Digital display:
Pull the turn signal lever (flash-to-pass) towards the steering
wheel for at least 2 seconds.
Performance monitor:
Press "Clear" key.
This input procedure is canceled. The original data
still apply.
2 Completing the program
mode
Diagnosis or input is completed when a procedure has come
to an end and the data has been stored in the memory.
Digital display: (on tractors with
PowrQuad Plus transmission only)
Keep pulling the turn signal lever (flash-to-pass) towards the
steering wheel until the display shows the normal operating mode.
Performance monitor:
Press "Clear" key.
or
Turn the main (key) switch off.
Before you switch the main (key) switch on again, wait
at least 5 seconds while an exchange of data takes place between the
control units.
The control unit is now in its normal operating mode.
|
|
OULXE59,00104D1-19-20031201
|
|