Disconnecting Hydraulic Hoses-5025

IMPORTANT: To prevent tractor hydraulic system damage, pressure return jumper hose quick-disconnect coupler MUST be connected to pressure quick-disconnect coupler, when backhoe is detached.

1. Disconnect backhoe pressure and return hoses (C and D) from tractor.

2. Connect jumper hose (A) to power beyond coupler (B).

3. Connect backhoe pressure hose male quick disconnect coupler (C) to backhoe pressure return hose female quick disconnect coupler (D).


A-Jumper Hose
B-Power Beyond Coupler
C-Backhoe Pressure Hose
D-Backhoe Return Hose

LV10980
LV10981