Open the fuel shut-off valve.
-
Lock the park brake.
-
Move the transmission range shift lever to the N (neutral) position.
-
Push the PTO switch knob down to the disengaged/off position.
-
CAUTION: Check to be sure area is clear of any bystanders before
lowering implements to the ground.
Lower any implements to the ground.
-
Set the engine speed hand throttle to the 1/2-3/4 fast position.
-
Turn ignition key switch to the ON position.
-
Check indicator lamps:
-
IMPORTANT: Starter may be damaged if starter is operated for
more than 20 seconds at a time:
Wait two minutes before
trying again if engine does not start.
Turn key switch to START position. Release key when engine starts.
-
Check indicator lights:
-
Engine oil pressure light should go out within 5 seconds.
NOTE: Set engine speed at full throttle if indicator light does
not go out after 10 seconds.
-
Alternator/battery charging light should go out within 10 seconds.
-
If indicator lights stay on longer than the given time interval,
stop engine and check for cause.
-
IMPORTANT: In cold weather, run engine several minutes to allow
engine oil and transmission oil to warm.
NOTE: It is normal for the engine to be louder and for blue-white
exhaust smoke to be present during engine warm-up. The amount of exhaust
smoke depends on air temperature.
Set the engine speed hand throttle to the 1/2 fast position
for 1 minute without load.