Diesel Engine Coolant

Preferred coolants:

The following pre-mix engine coolants are preferred:

  • John Deere Cool-Gard™ II
  • John Deere Cool-Gard™ II PG

Not all Cool-Gard™ II pre-mix products are available in all countries.

Use Cool-Gard™ II PG when a non-toxic coolant formulation is required.


Additional Recommended Coolants

The following engine coolant is also recommended:

  • John Deere Cool-Gard™ II Concentrate in a 40—60% mixture of concentrate with quality water.

IMPORTANT: Avoid damage! When mixing coolant concentrate with water, do not use less than 40% or greater than 60% concentration of coolant. Less than 40% gives inadequate additives for corrosion protection. Greater than 60% can result in coolant gelation and cooling system problems.


Other Coolants

Other ethylene glycol or propylene glycol base coolants may be used if they meet one of the following specifications:

  • Pre-mix coolant meeting ASTM D6210 requirements
  • Coolant concentrates meeting ASTM D6210 requirements in a 40% to 60% mixture of concentrate with quality water
  • Pre-mix coolant meeting ASTM D3306 requirements
  • Coolant concentrates meeting ASTM D3306 requirements in a 40% to 60% mixture of concentrate with quality water

If coolant meeting one of these specifications is unavailable, use a coolant concentrate or pre-mix coolant that has a minimum of the following chemical and physical properties:

  • Is formulated with a quality nitrite-free additive package.
  • Protects the cooling system metals (cast iron, aluminum alloys, and copper alloys such as brass) from corrosion.

Water Quality

Water quality is important to the performance of the cooling system. Distilled, deionized, or demineralized water is recommended for mixing with ethylene glycol base engine coolant concentrate.


Coolant Drain Intervals

Drain and flush the cooling system and refill with fresh coolant at the indicated interval, which varies with the coolant used.

When Cool-Gard™ II or Cool-Gard™ II PG is used, the drain interval is 6 years or 6000 operating hours.

If a coolant other than Cool-Gard™ II or Cool-Gard™ II PG is used, reduce the drain interval to 2 years or 2000 operating hours.

IMPORTANT: Avoid Damage!

  • Do not use cooling system sealing additives or antifreeze that contains sealing additives.
  • Do not mix ethylene glycol and propylene glycol base coolants.
  • Do not use coolants that contain nitrites.


Cool-Gard is a trademark of Deere & Company