Operate Hydraulic Dual Selective Control Valve (SCV)
Avoid injury! Escaping fluid under high pressure can
penetrate the skin and cause serious injury. Avoid the hazard by relieving
pressure before connecting hydraulic or other lines. Tighten all connections
before applying pressure.
-
Search for leaks with a piece of cardboard. Protect hands and
body from high-pressure fluids.
-
If an accident occurs, see a doctor immediately. Any fluid injected
into the skin must be surgically removed within a few hours or gangrene
may result. Doctors unfamiliar with this type of injury should reference
a knowledgeable medical source. Such information is available from
Deere & Company Medical Department in Moline, Illinois, United
States. In the United States and Canada only, this information may
be obtained by calling 1-800-822-8262.
This machine series is equipped with a hydraulic selective control
valve (SCV) and hydraulic outlets to operate hydraulically driven
implements.
LVAL38294-UN-21AUG12
A - Blue
B - Black
C - Yellow
D - Red
The machine-mounted hydraulic outlets are female quick couplers
color coded for easy hookup.
Implement hydraulic hoses are also color coded. Match the color
coded hose ends to the color coded hydraulic couplers on the machine
when making connections.
LV27356-UN-03MAY17
E - Dual SCV Lever
F - Information Label
When the implement hydraulic hoses are connected to the yellow
and black couplers, move the dual SCV lever (E) left to divert fluid
to the black connector line and return through the yellow connector
line. Move the lever right to divert fluid to the yellow connector
line and return through the black connector line. Move the lever to
the full right or “regeneration position” to divert fluid to the black
connector line for faster loader bucket dumping.
When the implement hydraulic hoses are connected to the red
and blue couplers, move the dual SCV lever (E) rearward to divert
fluid to the blue connector line and return through the red connector
line. Move the lever forward to divert fluid to the red connector
line and return through the blue connector line. Move the lever to
the full forward or “float” position to remove pressure in both connector
lines and allow fluid to flow back and forth between the lines. The
lever may be left in the “float” position.
Refer to the information label (F) for assistance. See your
implement operator manual for implement functions which correspond
to lever positions.
Avoid damage! To prevent contamination of female
quick couplers, install color-coded hose ends in the couplers when
not being used.
|
UP00731,0000167-19-20170220
|
|