Use Rear Outlet SCV
Avoid injury! Escaping fluid under high pressure can
penetrate the skin and cause serious injury. Avoid the hazard by relieving
pressure before connecting hydraulic or other lines. Tighten all connections
before applying pressure.
-
Search for leaks with a piece of cardboard. Protect hands and
body from high-pressure fluids.
-
If an accident occurs, see a doctor immediately. Any fluid injected
into the skin must be surgically removed within a few hours or gangrene
may result. Doctors unfamiliar with this type of injury should reference
a knowledgeable medical source. Such information is available from
Deere & Company Medical Department in Moline, Illinois, U.S.A.
In the United States and Canada only, this information may be obtained
by calling 1-800-822-8262.
This machine model series can be equipped with an optional hydraulic
third selective control valve (SCV) and hydraulic outlets to operate
hydraulically driven implements.
The machine-mounted hydraulic outlets are female quick couplers.
Using Rear SCV Control Switch
LV28562-UN-23MAY17
LV28563-UN-23MAY17
Cab Shown; Open Operator Station Similar
A - Top of Control Switch
B - Bottom of Control Switch
C - Upper Outlet
D - Lower Outlet
The rear outlet SCV may be operated in a momentary condition
to operate attachments such as extending or retracting a hydraulic
cylinder. The attachment will receive full hydraulic flow in direct
response to the use of the control switch
-
Depress the top of control switch (A) to allow flow from the
circuit out the lower outlet (D) and return to the machine through
the upper outlet (C).
-
Depress the bottom of control switch (B) to allow flow from
the circuit out the upper outlet (C) and return to the machine through
the lower outlet (D).
Before connecting or disconnecting couplers, relieve pressure
on both rear outlets. Lower the implement to the ground, tractor off
and the ignition in the on position. Cycle the SCV control switch
(A and B) a few times.
Avoid damage! To prevent contamination of female
quick couplers, color-coded hose ends should be installed in the couplers
when not being used.
|
DB71512,0000252-19-20170523
|
|