Use Rear Outlet SCV

Avoid injury! Escaping fluid under high pressure can penetrate the skin and cause serious injury. Avoid the hazard by relieving pressure before connecting hydraulic or other lines. Tighten all connections before applying pressure.

  • Search for leaks with a piece of cardboard. Protect hands and body from high-pressure fluids.
  • If an accident occurs, see a doctor immediately. Any fluid injected into the skin must be surgically removed within a few hours or gangrene may result. Doctors unfamiliar with this type of injury should reference a knowledgeable medical source. Such information is available from Deere & Company Medical Department in Moline, Illinois, U.S.A. In the United States and Canada only, this information may be obtained by calling 1-800-822-8262.

This machine model series can be equipped with an optional hydraulic third selective control valve (SCV) and hydraulic outlets to operate hydraulically driven implements.

The machine-mounted hydraulic outlets are female quick couplers.


Using Rear SCV Control Switch

LV28562
LV28562-UN-23MAY17

LV28563
LV28563-UN-23MAY17

Cab Shown; Open Operator Station Similar

A - Top of Control Switch

B - Bottom of Control Switch

C - Upper Outlet

D - Lower Outlet


The rear outlet SCV may be operated in a momentary condition to operate attachments such as extending or retracting a hydraulic cylinder. The attachment will receive full hydraulic flow in direct response to the use of the control switch

  1. Depress the top of control switch (A) to allow flow from the circuit out the lower outlet (D) and return to the machine through the upper outlet (C).

  2. Depress the bottom of control switch (B) to allow flow from the circuit out the upper outlet (C) and return to the machine through the lower outlet (D).

    Before connecting or disconnecting couplers, relieve pressure on both rear outlets. Lower the implement to the ground, tractor off and the ignition in the on position. Cycle the SCV control switch (A and B) a few times.

    Avoid damage! To prevent contamination of female quick couplers, color-coded hose ends should be installed in the couplers when not being used.

DB71512,0000252-19-20170523