Checking Cab Roll-Over Protection System Installation

Avoid injury! To maintain operator protection and ROPS certification:

  • Do not repair or revise the ROPS.
  • Any alteration of the ROPS must be approved by the manufacturer.

Avoid damage! Make certain all parts are installed correctly. If cab protection system is loosened or removed for any reason, tighten mounting cap screws to specification.

The protection offered by cab protection system will be impaired if cab protection system is subjected to structural damage, as in an overturn incident, or is in any way altered by welding, bending, drilling, or cutting. A damaged cab protection system should be replaced, not reused. Any alteration to the cab protection system must be approved by the manufacturer.

LV29356
LV29356-UN-11SEP17

LV17764
LV17764-UN-14MAY13

A - Floor Mat

B - Mounting Hardware


  1. When installation of equipment on a machine necessitates loosening or removing cab protection system, mounting cap screws should be tightened to specification.

  2. Inspect cab protection system mounting hardware every 50 hours for proper torque or replacement.

  3. Lift up rubber floor mat (A) to access front mounting hardware.

  4. Remove fastener and pull insulation liner away from fender to access rear mounting hardware (B).

  5. Tuck the insulation liner under the fender panels when complete.

  6. Tighten the mounting hardware to 260 N•m (192 lb.-ft.)

UP00731,0000434-19-20170829