Vibration Measurements
|
Hand/Arm Measured Per EN ISO5395-1
|
|
X305R with 42 in rear discharge mower deck .............. 4.1 ±
0.5 m/s2
|
|
Uncertainty K ..............0.5 m/s2
|
|
Whole Body Measured Per EN ISO5395-1
|
|
X305R with 42 in Rear discharge mower deck .............. 1.1 ±
0.1 m/s2
|
|
Uncertainty K ..............0.1 m/s2
|
NOTE: The value listed above represents the weighted root means
square acceleration to which the whole body is subjected on a representative
machine during actual mowing and transport conditions. The acceleration
value depends upon the roughness of the ground, the speed at which
the tractor is operating and the operator weight and driving habits.
Measurements were obtained through actual field data according to
STD Procedure in EN ISO5395-1.
|
|
OUMX068,00007C8-19-20140522
|
|