Diesel Engine Coolant
Preferred coolants:
The following pre-mix engine coolants are preferred:
-
John Deere COOL-GARD™ II
-
John Deere COOL-GARD II PG
Not allCOOL-GARD II pre-mix products are available in all countries.
Use COOL-GARD II PG when a non-toxic coolant formulation is
required.
Additional Recommended Coolants
The following engine coolant is also recommended:
-
John Deere COOL-GARD II Concentrate in a 40—60% mixture
of concentrate with quality water.
IMPORTANT: When mixing coolant concentrate with water, do not
use less than 40% or greater than 60% concentration of coolant. Less
than 40% gives inadequate additives for corrosion protection. Greater
than 60% can result in coolant gelation and cooling system problems.
Other Coolants
Other ethylene glycol or propylene glycol base coolants may
be used if they meet one of the following specifications:
-
Pre-mix coolant meeting ASTM D6210 requirements
-
Coolant concentrate meeting ASTMD6210 requirements in a 40%
to 60% mixture of concentrate with quality water
-
Pre-mix coolant meeting ASTM D3306 requirements
-
Coolant concentrate meeting ASTM D3306 requirements in a 40%
to 60% mixture of concentrate with quality water
If coolant meeting one of these specifications is unavailable,
use a coolant concentrate or pre-mix coolant that has a minimum of
the following chemical and physical properties:
-
Is formulated with a quality nitrite-free additive package.
-
Protects the cooling system metals (cast iron, aluminum alloys,
and copper alloys such as brass) from corrosion.
Water Quality
Water quality is important to the performance of the cooling
system. Distilled, deionized, or demineralized water is recommended
for mixing with ethylene glycol base engine coolant concentrate.
Coolant Drain Intervals
Drain and flush the cooling system and refill with fresh coolant
at the indicated interval, which varies with the coolant used.
When COOL-GARD II or COOL-GARD II PG is used, the drain interval
is 6 years or 6000 hours of operation.
If a coolant other than COOL-GARD II or COOL-GARD II PG is used,
reduce the drain interval to two years or 2000 hours of operation.
IMPORTANT: Do not use cooling system sealing additives or antifreeze
that contains sealing additives.
IMPORTANT: Do not mix ethylene glycol and propylene glycol base
coolants.
IMPORTANT: Do not use coolants that contain nitrites.
|
COOL-GARD is a trademark of Deere & Company
|
OUO2004,00003EA-19-20130919
|
|