Park machine safely on a level surface. (See Parking Safely
in the SAFETY section.)
-
Move hydraulic control lever back and forth a few times to relieve
system pressure.
-
IMPORTANT: Hot hydraulic oil will expand and show incorrect
oil level. Check oil level:
• When oil is cold.
• With engine not running.
Allow machine to cool.
-
MXAL46407-UN-05APR13
Locate transaxle oil reservoir (A) at rear of machine. Reservoir
is marked FULL (B) and ADD (C).
-
IMPORTANT: Contamination can damage the hydraulic system. Clean
thoroughly around reservoir fill cap before opening.
If oil level is low, clean area around reservoir cap (D).
-
MXAL46408-UN-05APR13
Remove cap and filter (E).
-
Add John Deere Low Viscosity HY-GARD™ (J20D) until oil
level is at FULL mark on reservoir.
-
Install filter and cap.
-
Start engine.
-
Operate machine forward and in reverse several times.
-
Park machine safely on a level surface. (See Parking Safely
in the SAFETY section.)
-
Wait at least 3 minutes for hydraulic oil to cool.
-
Check oil level again. Add oil if necessary.