Operating Machine in the Field

1. Unfold boom. (See UNFOLDING BOOM in this section.)

AG,OUO1011,249 -19-27APR99-1/6


2. Depress raise/lower switch (A) to position boom at desired operating height.


A-Raise/Lower Switch

N42191FF

AG,OUO1011,249 -19-27APR99-2/6


3. Depress switch (A) to engage solution pump.

4. If agitation is desired, turn agitation system "ON" using switch (B).


A-Solution Pump Switch
B-Agitation System "ON" Switch

N42190SE

AG,OUO1011,249 -19-27APR99-3/6


5. Press "RUN" button on monitor to view spray operation display on monitor screen.

N50317

AG,OUO1011,249 -19-27APR99-4/6


6. Push hydro lever (A) slowly forward to start forward motion.

7. Press left and/or right solution spray control switches (B) (and center switch-if equipped), to turn individual boom spray sections "ON".

8. Depress Master ON switch (C) to turn spray system "ON".


A-Hydro Lever
B-Left/Right/Center Spray Control Switches
C-Master Spray Switch

N42191UA

AG,OUO1011,249 -19-27APR99-5/6


IMPORTANT: Spray system shut-down is not immediate. Solution flow will continue for a short period of time (approximately 1-3 seconds) after depressing OFF switch. For best response time and coverage, turn spray OFF as you slow for row end.

9. At row end, depress right-hand side of Master ON/OFF switch (A) to stop spraying. All other switches can remain in pre-set positions.

IMPORTANT: Spray system start-up is not immediate. To overcome delayed response, depress ON switch while moving forward to start spraying just before solution is actually needed.

10. When aligned with next row, depress left-hand side of Master ON/OFF switch (B) to resume spraying.

N42191UB


A-Right Hand Side of Master ON/OFF Switch
B-Left-Hand Side of Master ON/OFF Switch

AG,OUO1011,249 -19-27APR99-6/6