Using Booster Battery

N42191ZK


A-Positive Post


B-Positive Post


C-Negative Post


D-Engine Block

causym CAUTION: Gas given off by batteries is explosive. Keep sparks and flames away from battery. Make last connection and first disconnection at a point away from battery.

IMPORTANT: Always connect starter cable to positive (+) terminal of battery and battery ground cable to negative (-) terminal of battery. Reversed polarity in battery or alternator can result in permanent damage to electrical system.

1. Connect positive (+) cable to positive post (A) of discharged battery and the other end of the same cable to positive post (+) (B) of booster battery.

2. Connect second cable (negative) (-) to negative post (C) of booster battery.

3. Connect the other end of the negative (-) cable to the engine block (D) of the stalled machine, away from the battery. Stand clear.

4. Start machine and remove cables in reverse order of connection.

AG,OUO1011,288 -19-28APR99-1/1