Cleaning Solution Strainer (If Equipped)

causym CAUTION: Spray system can contain hazardous material which can cause serious injury or death to you or others. Wear protective clothing, eyewear and gloves. Drain solution and clean strainer in an area where people, animals, vegetation, and water supply, etc. cannot be contaminated.

1. Remove plug (A) from strainer assembly (B) to drain sediment.

2. If necessary, remove end cap (C) and strainer screen from strainer housing.

IMPORTANT: Strainer assembly can leak if O-ring is not in place and in good condition. Verify O-ring is in place and in good condition when assembling strainer.

3. If end cap and strainer screen was removed, install strainer screen, end cap, and plug on strainer housing.

If end cap and strainer screen were not removed, install plug.

4. Check strainer assembly for leaks. Repair if necessary.

N42191MI


A-Plug
B-Strainer Assembly
C-End Cap

AG,OUO1011,367 -19-29APR99-1/1