Clean Foam Compressor Intake Filter-50 Hours

Remove intake filter (A) from compressor and clean by back blowing through fitting with air pressure at 210 kPa (2 bar) (30 psi).


A-Intake Filter

N42190FP

AG,OUO1011,427 -19-29APR99-1/1