Service Battery-200 Hours

causym CAUTION: Battery gas can explode. Keep sparks and flames away from batteries. Use a flashlight to check battery electrolyte level.

Never check battery charge by placing a metal object across the posts. Use a voltmeter or hydrometer.

Always remove grounded (-) battery clamp first and replace it last.

causym CAUTION: Sulfuric acid in battery electrolyte is poisonous. It is strong enough to burn skin, eat holes in clothing, and cause blindness if splashed into eyes.

Avoid the hazard by:

1. Filling battery in a well-ventilated area.
2. Wearing eye protection and rubber gloves.
3. Avoiding breathing fumes when electrolyte is added.
4. Avoiding spilling or dripping electrolyte.
5. Use proper jump start procedure.

If you spill acid on yourself:

1. Flush your skin with water.
2. Apply baking soda or lime to help neutralize the acid.
3. Flush your eyes with water for 15-30 minutes. Get medical attention immediately.

If acid is swallowed:

1. Do not induce vomiting.
2. Drink large amounts of water or milk, but do not exceed 2 L (2 quarts).
3. Get medical attention immediately.

WARNING: Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and reproductive harm. Wash hands after handling.

TS204
N42190RL
TS203

NX,4700,N14 -19-07AUG97-1/2


1. Keep all connections clean and tight. Remove corrosion, and wash terminals with a solution of baking soda and water.

2. Check the specific gravity of the electrolyte in each battery cell. Charge battery if reading is below 1.215.

IMPORTANT: Do not add water in freezing weather unless machine operates at least 30 minutes.

3. Check level of electrolyte in each cell. If low, fill to bottom of filler necks with CLEAN, SOFT water. DO NOT OVERFILL.

4. Coat terminals with small amount of grease and replace terminal shields.