ROW-TRAK
guidance system allows operator hands-off steering of machine by aligning row units with rows and then activating a switch on hydro lever.
At the end of row, turning steering wheel will deactivate system and return manual control of machine. After system has been deactivated, operator must repeat row alignment and switch activation procedures to activate ROW-TRAK
system.
See Operating ROW-TRAK
in this section for detailed description of operation.
If the ROW-TRAK
system is installed at factory or by dealer, all set-up programming and diagnostics are performed at factory or dealer prior to machine delivery.
Channels 1 and 2 modify ROW-TRAK
response of machine. Channel 5 establishes an automatic valve set-up that records level of supply voltage where steering valve starts to turn guide tires. Channels 3, 4, and 6-10 are used for diagnosing problems on machine. For descriptive information see Performance
|
Channels-1 and 2, Perform ROW-TRAK
Automatic Valve Biasing-Channel 5, and Diagnostic Channels-3, 4, and 6-10.
NOTE:
Channels 1-10 are only used during diagnosing and correcting ROW-TRAK
performance problems. Refer to ROW-TRAK
in Troubleshooting section of this manual for details.
Operation and set-up procedures in this section include:
-
Operating ROW-TRAK
-
Field ROW-TRAK
Learn
-
Static ROW-TRAK
Learn
-
Entering ROW-TRAK
Calibration Mode
-
Performance Channels- 1 and 2
-
Diagnostic Channels-3 and 4
-
Perform ROW-TRAK
Automatic Valve Biasing-Channel 5
-
Diagnostic Channels-6-10
-
ROW-TRAK
Circuit Diagnostic Codes
|