Using the Moistener Flush System

To ensure lowest solution usage when spindle buildup is observed, activate moistener flush system to clean spindles in the following order.

NOTE: Some conditions (green sappy plants) will require more frequent flushing.

With units and fan running, depress moistener flush switch (A) on the cab floor:

  • At each basket unload for 10-15 seconds (normal conditions).
  • At one end of field for 4-5 seconds (tough staining conditions).
  • At both ends of field for 4-5 seconds (extreme staining conditions).

When flushing at a turn row, depress foot pedal as row units are just starting to raise. Release pedal halfway through turn (approximately 4-5 seconds). This allows excess solution to be removed before re-entering the row.

DO NOT operate flush system in row while picking or plugging may result.

N42132DU


A-Moistener Flush Switch

AG,OUO1011,1135 -19-08SEP99-1/1