Adjusting Opener Down-Pressure and Seed Depth (John Deere Tractors With Closed Center Hydraulic Systems)
IMPORTANT:
Valve (D) must be in open position.
IMPORTANT:
Adjust opener down-pressure, as required, to keep opener gauge wheels in firm contact with soil. DO NOT use more down-pressure than necessary or damage could result to machine.
IMPORTANT:
Active hydraulic system requires a tractor with closed-center or pressure/flow compensated hydraulics. A conversion kit and installation instructions are available for tractors with open-center hydraulics.
1.
Lower the openers by pushing FORWARD on SCV lever. Valve (D) must be LOCKED OPEN to provide constant pressure/flow to openers. See INSTALLING LEVER LOCK CLIP-TRACTORS WITH MECHANICAL SCV CONTROLS in Preparing The Tractor section.
-
Use clip to lock lever forward on John Deere tractors equipped with SOUND-GARD
Body.
-
On John Deere 7000 Series tractors, rotate valve detent selector to MOTOR POSITION to lock lever in forward position.
-
On 8000 Series Tractors, set the time detent knob to "C" for continuous flow. Push the SCV I lever forward to "click" detent position.
2.
While watching pressure gauge (C), adjust opener down-pressure by rotating knob (A). Once set, lock knob in position with wheel (B).
-
NEVER operate outside the GREEN zone.
-
NEVER operate in RED zone.
|
A-Valve Adjusting Knob
B-Valve Knob Lock
C-Pressure Gauge
D-Valve
|