Preparing Hydraulic System
1.
Check hydraulic oil level. Fill if necessary.
2.
WING-FOLD/UNFOLD: Press SCV II selector button (A), and turn flow control knob (B) to fast (rabbit) position.
3.
Turn time detent knob (C) until display reads 19 seconds. If this is not enough time to completely fold/unfold wings, time detent button may be set to CONTINUOUS. Tractor hydraulic pump will continue to operate after fold/unfold cylinders have stopped moving. This is normal and not harmful. However, shutting off pump by moving SCV lever to any position after lever has returned to NEUTRAL is recommended.
A-SCV II Selector Button
B-Flow Control Knob
C-Time Detent Knob
|