Diagnostic Channels-3 and 4

Channel 3-Crop Sensor "Learned" Value

NOTE: This channel is for diagnostic purposes only, there is no operator adjustment.

This channel displays the "learned" values of the crop sensor. The system must first go through the "learn mode" before values will be displayed.

This channel can be used to ensure that the input signal coming from the crop sensor is valid. This channel can be monitored while driving machine through the field.

Exit calibration mode by turning ROW-TRAK on/off switch to OFF position. To change channels, push the cal/learn switch into the cal position (push down on the upper half of the switch) and rotate the offset adjust knob to change channels as desired, then release the cal/learn switch.

Channel 4-Rear Wheel Sensor "Learned" Value

NOTE: This channel is for diagnostic purposes only, there is no operator adjustment.

This channel displays the "learned" value of the rear wheel sensor. The system must first go through the "learn mode" before values will be displayed.

This channel can be used to ensure that the input signal coming from the rear wheel sensor is valid. This channel can be monitored while driving machine through the field.

Exit calibration mode by turning ROW-TRAK on/off switch to OFF position. To change channels, push the cal/learn switch into the cal position (push down on the upper half of the switch) and rotate the offset adjust knob to change channels as desired, then release the cal/learn switch.

NXD8M997645,T12 -19-22MAR06-1/1