NOTE:
If any errors occur during calibration procedures, error codes will be displayed on ADU.
The condition causing the error must be corrected before calibration procedure can be continued.
Code E01
-Factory calibration must be done before header calibration.
Code E21
-Left raise valve deadband not consistent within 30 mA.
Code E22
-Left raise valve deadband not found.
Code E23
-Left raise valve deadband greater than 750 mA.
Code E24
-Left raise valve deadband less than 150 mA.
Code E26
-Left lower valve deadband not consistent within 30 mA.
Code E27
-Left lower valve deadband not found.
Code E28
-Left lower valve deadband greater than 750 mA.
Code E29
-Left lower valve deadband less than 150 mA.
Code E31
-Right raise valve deadband not consistent within 30 mA.
Code E32
-Right raise valve deadband not found.
Code E33
-Right raise valve deadband greater than 750 mA.
Code E34
-Right raise valve deadband less than 200 mA.
Code E36
-Right lower valve deadband not consistent within 30 mA.
|
Code E37
-Right lower raise valve deadband not found.
Code E38
-Right lower valve deadband greater than 750 mA.
Code E39
-Right lower valve deadband less than 150 mA.
Code E41
-Left outer #1 height sensor voltage less than 0.5 V.
Code E42
-Left outer #1 height sensor voltage greater than 4.5 V.
Code E43
-Left outer #1 height sensor voltage noisy or going backwards.
Code E44
-Left outer #1 height sensor voltage range less than 2.0 V.
Code E45
-Left outer #1 height sensor lower voltage greater than 2.5 V.
Code E46
-Left outer #1 height sensor upper voltage less than 2.5 V.
Code E51
-Left outer #2 height sensor voltage less than 0.5 V.
Code E52
-Left outer #2 height sensor voltage greater than 4.5 V.
Code E53
-Left outer #2 height sensor voltage noisy or going backwards.
Code E54
-Left outer #2 height sensor voltage range less than 2.0 V.
Code E55
-Left outer #2 height sensor lower voltage greater than 2.5 V.
Code E56
-Left outer #2 height sensor upper voltage less than 2.5 V.
|