Service Recommendations For Flat Face O-Ring Seal Fittings
1.
Inspect the fitting sealing surfaces and O-ring. They must be free of dirt or defects.
2.
Lubricate O-rings and install into grove using petroleum jelly to hold in place.
3.
Index angle fittings and tighten by hand pressing joint together to insure O-ring remains in place.
4.
Tighten fitting or nut to torque value shown on the chart. Do not allow hoses to twist when tightening fittings, use backup wrench on straight hose couplings.
IMPORTANT:
Tighten fittings to 150% of listed torque value if indexing is necessary or if fitting is attached to an actuating devise.
Tighten fittings to 50% of listed torque value if used in aluminum housing.
|