Round Module Builder latch cylinder does not extend/retract or does so unevenly.
|
Hydraulic oil level low.
|
Check system for leak and repair. Fill reservoir to appropriate level.
|
|
|
Break in power to valve coil.
|
Inspect electrical connectors and harness. Repair as needed.
|
|
Gate cylinder will not extend or retract.
|
Hydraulic lock valve engaged.
|
Disengage hydraulic lock valve.
|
|
|
Hydraulic oil level low.
|
Check system for leak and repair. Fill reservoir to appropriate level.
|
|
|
Break in power to valve coil.
|
Inspect electrical connectors and harness. Repair as needed.
|
|
Round module builder rockshaft cylinder will not extend or retract.
|
Hydraulic oil level low.
|
Check system for leak and repair. Fill reservoir to appropriate level.
|
|
|
Break in power to valve coil.
|
Inspect electrical connectors and harness. Repair as needed.
|
|
Wrap floor cylinder will not extend/retract
|
Hydraulic oil level low.
|
Check system for leak and repair. Fill reservoir to appropriate level.
|
|
|
Break in power to valve coil.
|
Inspect electrical connectors and harness. Repair as needed.
|
|
Wrap box cylinder will not extend/retract or does so unevenly.
|
Hydraulic oil level low.
|
Check system for leak and repair. Fill reservoir to appropriate level.
|
|
|
Oil not properly warmed up.
|
When operating in temperatures below 12°C (10°F), run-in picker 10-15 minutes to warm up hydraulic oil.
|
|
|
Break in power to valve coil.
|
Inspect electrical connectors and harness. Repair as needed.
|