Round Module Builder

Symptom Problem Solution

Round Module Builder latch cylinder does not extend/retract or does so unevenly.

Hydraulic oil level low.

Check system for leak and repair. Fill reservoir to appropriate level.

Break in power to valve coil.

Inspect electrical connectors and harness. Repair as needed.

Gate cylinder will not extend or retract.

Hydraulic lock valve engaged.

Disengage hydraulic lock valve.

Hydraulic oil level low.

Check system for leak and repair. Fill reservoir to appropriate level.

Break in power to valve coil.

Inspect electrical connectors and harness. Repair as needed.

Round module builder rockshaft cylinder will not extend or retract.

Hydraulic oil level low.

Check system for leak and repair. Fill reservoir to appropriate level.

Break in power to valve coil.

Inspect electrical connectors and harness. Repair as needed.

Wrap floor cylinder will not extend/retract

Hydraulic oil level low.

Check system for leak and repair. Fill reservoir to appropriate level.

Break in power to valve coil.

Inspect electrical connectors and harness. Repair as needed.

Wrap box cylinder will not extend/retract or does so unevenly.

Hydraulic oil level low.

Check system for leak and repair. Fill reservoir to appropriate level.

Oil not properly warmed up.

When operating in temperatures below 12°C (10°F), run-in picker 10-15 minutes to warm up hydraulic oil.

Break in power to valve coil.

Inspect electrical connectors and harness. Repair as needed.

OUO1078,0000276 -19-27MAR09-1/1