Adjusting Metering Valves-Tractors With Electro/Hydraulic SCV Controls

1. Press SCV I selector button (A) and turn flow control knob (B) to rabbit position.

2. Turn time detent knob (C) until display reads "C" (continuous). The time can be decreased for actual time required to lift and lower opener rockshaft.


A-SCV I Selector Button
B-Flow Control Knob
C-Time Detent Knob

N48104

AG,OUO1074,432 -19-22FEB00-1/2


3. If equipped with markers, press SCV II selector button (A) and turn flow control knob (B) to fast/rabbit position.

4. Turn time detent knob (C) until display reads "5" seconds. This can be increased or decreased depending on actual time required to lower and raise markers.


A-SCV II Selector Button
B-Turn Flow Control Knob
C-Time Detent Knob

N48105

AG,OUO1074,432 -19-22FEB00-2/2