Opener Down-Pressure System-Tractor With Open-Center Hydraulics

Symptom Problem Solution

Down-Pressure Does Not Function.

Lock-up valve closed.

Open lock-up valve.

Pressure Gauge Shows Zero When Openers Are Down.

SCV lever in float position.

Put SCV lever in neutral position.

SCV lever not held forward long enough to charge down-pressure system.

When lowering openers, hold SCV lever forward long enough for down-pressure system to reach pre-set pressure as shown on pressure gauge.

Openers Do Not Maintain Proper Ground Contact.

SCV lever not held forward long enough to charge down-pressure system.

When lowering openers, hold SCV lever forward long enough for down-pressure system to reach pre-set pressure as shown on pressure gauge.

Slow internal hydraulic leakage. (Normal with all hydraulic systems.)

Hold SCV lever forward long enough for down-pressure system to reach pre-set pressure as shown on pressure gauge.

More hydraulic pressure required.

Increase pre-set hydraulic pressure.

Pre-set Pressure Does Not Lower When Turning Valve Knob Counterclockwise.

Open center attachment traps oil in system until openers are raised.

Raise and lower openers to reset to lower pressure.

Pressure valve sticks.

Disassemble valve and clean.

Pre-set Pressure Does Not Rise When Turning Valve Knob Clockwise.

No pressure to adjusting valve.

Hold SCV #1 in forward position for a few seconds.

Hose couplers not connected properly to tractor.

Ensure that hose couplers are connected to proper SCV and locked.

Openers Drift Down After Being Raised.

There may be contamination in the V1 ball check assembly or the piston seal in the hydraulic cylinder may be leaking.

Close transport valve and disconnect hydraulic hoses to the tractor SCV. If openers still continue to drop, see your John Deere dealer.

AG,OUO1074,542 -19-22FEB00-1/1