Preparing for Storage
CAUTION:
Reduce compressed air to less than 210 kPa (2 bar) (30 psi) when using for cleaning purposes. Clear area of bystanders, guard against flying debris, and wear personal protection equipment, including eye protection.
IMPORTANT:
Compressed air (dry) cleaning method is recommended to prevent gum-like deposits (left by water wash) from forming on seed box components and/or blocking product passages.
1.
Empty drill box(es) and clean caked deposits from box(es). See CLEANING GRAIN BOX and CLEANING FERTILIZER BOX in this section.
COMPRESSED AIR (DRY) CLEANING:
CAUTION:
Do not allow residue from box(es) washing to contaminate well or ground water.
IMPORTANT:
If compressed air is not available for cleaning, water wash method may be used provided seed boxes are thoroughly dried after cleaning. Drying takes time since moisture trapped in bearing areas is slow to drain or evaporate.
Thoroughly clean inside of box(es) using compressed air. A good dry cleaning is preferable to poor washing and drying.
WATER WASH (WET) CLEANING:
Wash machine thoroughly, inside and out. Wipe surfaces and components dry.
|