Locking SCV Lever for Active Down-Pressure Operation

NOTE: Clip keeps lever from returning to neutral to provide constant oil pressure to the down-pressure valve, as required, to maintain your chosen pressure setting.

55-60 Series Tractors: Lever lock clip (A) must be used to hold opener control lever in the down-pressure position (B). (To install lever lock clip see INSTALLING LEVER LOCK in Preparing The Tractor section.)

RW5845


A-Lever Lock Clip
B-Down-Pressure Position

OUO6074,000016B -19-05DEC00-1/3


6000, 6010, 7000 and 7010 Series Tractors: Rotate valve detent selector (A) to continuous detent to lock lever in forward position. Adjust flow rate valve (B) to rabbit position.


A-Detent Selector
B-Flow Rate Valve

A36437

OUO6074,000016B -19-05DEC00-2/3


Electro/Hydraulic SCV Controlled Tractors: Push SCV I control (A) forward until detent click is heard. With SCV I time knob set to "continuous", constant oil pressure will go to the down-pressure valve, as required, to maintain the chosen pressure setting.


A-SCV I

N48107

OUO6074,000016B -19-05DEC00-3/3