Clean Foam Compressor Louver Filters (If Equipped)-100 Hours

Remove louver filters (A) from compressor and wash in warm, soapy water, or blow dust free with compressed air at no more than 210 kPa (2 bar) (30 psi).


A-Louver Filters

N42190FO

AG,OUO6043,84 -19-28JUL99-1/1