18.3 m (60 ft) Boom Operation

Symptom Problem Solution

Outer boom section does not fold out or in or level up or down.

Failed solenoid coil or relay.

Replace coil or relay.

Damaged or corroded electrical connections.

Repair, replace or clean electrical connection.

Sticking hydraulic spool.

Remove hydraulic spool and clean or see your John Deere dealer.

Check valve stuck shut in load sense line.

Remove and clean check valve or see your John Deere dealer.

Load sense jamming valve not working.

See your John Deere dealer.

Faulty Switch.

Replace switch.

Faulty Cylinder.

See your John Deere dealer.

Plugged orifice or hydraulic line.

Remove and clean orifice or hydraulic line.

Boom does not raise or lower.

Failed solenoid coil or relay.

Replace coil or relay.

Damaged or corroded electrical connections.

Repair, replace or clean electrical connections.

Sticking hydraulic spool.

Remove hydraulic spool and clean or see your John Deere dealer.

Check valve stuck shut in load sense line.

Remove and clean check valve or see your John Deere dealer.

Load sense jamming valve not working.

See your John Deere dealer.

Faulty Switch.

Replace switch.

Faulty Lift Cylinders.

See your John Deere dealer.

Hydraulic compensator pressure not to specification

See your John Deere dealer.

NXH8,M68440,L12 -19-10JUL98-1/2


Symptom Problem Solution

One individual boom function does not stop when switch is released or slow to release.

Faulty solenoid valve.

Repair or replace solenoid valve.

Sticking hydraulic spool assembly.

Clean spool assembly or see your John Deere dealer.

Sticking or faulty switch.

Repair or replace switch.

NXH8,M68440,L12 -19-10JUL98-2/2