Flush Foam Marker System-Every 250 Hours

causym CAUTION: Contents under pressure. Vent pressure from tank prior to removing cap or servicing foam marker control unit. To vent tank, pull up on tank cap relief valve ring (A) or open tank vent valve (B).

IMPORTANT: Open tank vent valve prior to and during filling foam tank from bottom port. Open valve slowly to relieve tank pressure. Close valve after filling or foam marker will not operate.

1. Pull up on tank cap relief valve ring (A) or open tank vent valve (B) to relieve tank pressure.

2. Remove cap (C) and attach water hose to fill port.

3. Open fill valve (D).

4. Fill tank full of clean water.

5. Close fill valve. Disconnect hose from fill port, install cap and close vent valve.


A-Relief Valve Ring
B-Vent Valve
C-Cap
D-Handle

N76710
N76711

OUO6092,0000EF2 -19-11JUN07-1/4


6. Rotate fluid control knob (A) on rearward side of foamer control box fully counterclockwise.

7. Start engine.

8. Remove hose from tank and install cap or disconnect hose from fill port and close vent valve.


A-Fluid Control Knob

N67768

OUO6092,0000EF2 -19-11JUN07-2/4


N74748


A-Setup Softkey
B-Spray Setup Tab
C-Drop-Down Box
D-Foam Marker Switch

9. Select the Setup softkey (A) to view the setup menu.

10. Select the Spray Setup tab (B).

11. Select drop-down box (C) next to "Foam Marker" and select between:

  • "OFF"
  • "AUTO - LOW"
  • "AUTO - HIGH"
  • "MANUAL - LOW"
  • "MANUAL - HIGH"

12. Select "MANUAL LOW".

N74749

OUO6092,0000EF2 -19-11JUN07-3/4


13. Press left-hand side of foam marker control switch (A) and allow approximately one-half of the clean water in the solution tank to flow through left-hand collector.

14. Press right-hand side of control switch and allow remaining water in solution tank to flow through right-hand collector.

15. Shut off foamer system. (If storing the machine in a cold climate after performing this procedure, see Preparing Foam Marker System For Cold Weather Storage in the Storage section).

N63291

OUO6092,0000EF2 -19-11JUN07-4/4