| Symptom | Problem | Solution |
No foam coming out | Check system for air and solution leaks. | Correct leaks. |
| | Not enough foam concentrate in foam concentrate tank. | Fill foam concentrate tank. |
| | Check valve plugged. | Clean or replace check valve. |
| | Damaged or pinched air and/or liquid lines. | Repair lines. |
| | Flow control valve closed. | Open valve approximately two turns. |
| | Concentrate in tank is old. | Drain tank, rinse, and add fresh foam concentrate. |
| | Poor quality concentrate. | Use proper concentrate. |
| | Hard water. | Use water softener. |
| | Electric air shut-off valves not working. | Repair or replace electric valves. |
| | Anti-siphon valves not operating. | Repair or replace valves. |
| | Air shut-off valve not working. | Repair or replace valve. |
| | Air shut-off valve plugged. | Remove debris from valve. |
| | Foamer set to “OFF” on GSD. | Set to “Manual” or “Auto” mode. |
| | Foamer power supply fuse blown. | Replace fuse. |
| | OBA tank petcock open. | Close petcock. |